BAC-12xxxx/13xxxx/14xxxx Series FlexStat Controllers/Sensors/Thermostats

Previous Page

FlexStat Introduction:

What if you could have flexible, set-and-forget control over the indoor environmental quality (IEQ) in your building without the expense of a large building automation system? Well, now you can, with the KMC FlexStat. FlexStat IEQ control for your space optimizes temperature, humidity, and ventilation for your health and comfort...while saving energy at the same time. The FlexStat series of intelligent temperature/humidity/motion/CO2-sensing, wall-mounted, thermostat/controllers are native BACnet Advanced Application Controllers (B-AAC) for connection with a BACnet system. The FlexStat simplifies networked zone control for common HVAC equipment—such as packaged rooftop units, air handlers, fan coil units, and heat pumps—which can be controlled via the onboard libraries of programs built into the FlexStat. The on-board library of programs permits rapid configuration of a wide range of HVAC control applications via the FlexStat’s easy-to-use display and buttons. Plus, the standard library can be customized (using BACstage™ or TotalControl™) to meet the unique site needs and applicationspecific requirements of a particular project. With its built-in library of applications, just one FlexStat model can replace multiple competitor models. With a single BAC-120163CW, for example, all these application options can be selected from the menus:

CO2 and DCV Options
The air we breathe is critically important to our health since lurking potential contaminants can include dust, cigarette smoke, carbon dioxide, carbon monoxide, ozone, radon, VOCs (volatileorganic compounds), and various other chemical compounds from outgassing of building materials and cleaning supplies. Demand Control Ventilation (DCV) optimizes indoor air quality while still providing energy efficiency.

Two-piece design allows field rough-in and termination of field wiring to the backplate without needing the FlexStat at the site— permitting FlexStats to be bulk-configured offsite and plugged into the wired backplates at a later time if desired.

Features:

  • Air handling unit, with proportional heating andcooling valves, and with optional economizer, dehumidification, and/or fan status.

  • Fan coil unit, 2-pipe or 4-pipe, proportional or 2-position valves, with optional dehumidification (with 4-pipe option) and/or fan status.

  • Heat pump unit, with up to two compressor stages, and with optional auxiliary heat, emergency heat, dehumidification, and/or fan status.

  • Roof top unit, with up to two H/C stages, and with optional economizer, dehumidification, and/or fan status.

  • User-friendly, high-contrast, backlit, dotmatrix LCD display with five buttons for easy, plain-English menu-driven configuration and operation.

  • Multiple display options include selectable space temperature display precision, degrees F/C toggle, rotation values, display blanking, hospitality mode, and locked mode.

  • Temperature sensing (standard) and optional humidity, motion (with effective range of up to 33 feet), and CO2 sensing.

  • Six analog inputs for additional configurable remote external sensors, such as remote space temperature (with averaging, highest, and lowest options), remote CO2, outside air
    temperature, mixed air temperature, water supply temperature, fan status, and other sensors. Analog inputs accept industrystandard10K ohm thermistor sensors, dry contacts, or 0–12 VDC active sensors.

  • A total mix of nine relays (binary) and analog outputs.

  • Configurable password protection, with three levels of password-protected access to configuration, scheduling, and setpoint adjustment, prevents disruption of operation and configuration.

  • Built-in scheduling with Entire Week, Weekdays, Weekend, Individual Days, and Holidays options for easy configuration. Six On/Off and independent heating and cooling setpoint periods per day.

  • Integral peer-to-peer BACnet MS/TP LAN network communications on all devices (with configurable baud rate from 9600 to 76.8K baud), and “E” versions add BACnet over Ethernet, BACnet over IP, and BACnet over IP as Foreign Device.

Two-piece design allows field rough-in and termination of field wiring to the backplate without needing the FlexStat at the site—permitting FlexStats to be bulk-configured offsite and plugged into the wired backplates at a later time if desired.

 

 